SPECIFICATIONS
POWER REQUIREMENTS
5 VDC @ 500mA
BUS ARCHITECTURE
ISA Bus (PC/XT/AT/x86 Compatible)
INPUTS
Logic "0" 0 to 0.8 VDC
Logic "1" 3.5 to 5 VDC
All Inputs are pulled up to 5 VDC
CLOCK OUTPUT
HCMOS Type
source current 16mA (Voh=2.7V)
sink current 12mA (Vol=0.5V)
DIRECTION OUTPUT
HCMOS Type
source current 8mA (Voh=2.7V)
sink current 6mA (Vol=0.5V)
OUTPUT 1 - OUTPUT 10
Open-Collector Type
max individual sink current 500mA
total sink current 3.0A with 27% duty cycle
total sink current 2.4A with 35% duty cycle
total sink current 1.5A with 52% duty cycle
total sink current 0.8A with 100% duty cycle
Max Voltage 50V
+5 VDC OUTPUT
This is the computer's or backplane's power source; consult the appropriate manual for more information.
AMBIENT TEMPERATURE
0 to 50 degrees Celsius
SIZE
3.90 in. x 13.1 in.